Comparison of DNA concentration and bacterial pathogen PCR detection when using two DNA extraction kits for nasopharyngeal/oropharyngeal samples.

Dam Khan ORCID logo ; Shola-Able Thomas ; Peggy-Estelle Tientcheu ; Sambou MS Suso ; Christopher Dupont ; Brenda Kwambana-Adams ; Nuredin Ibrahim Mohammed ORCID logo ; Mark P Nicol ; Martin Antonio ORCID logo ; (2023) Comparison of DNA concentration and bacterial pathogen PCR detection when using two DNA extraction kits for nasopharyngeal/oropharyngeal samples. PLoS One, 18 (8). e0289557-. ISSN 1932-6203 DOI: 10.1371/journal.pone.0289557
Copy

INTRODUCTION: Several important human pathogens that cause life-threatening infections are asymptomatically carried in the Nasopharynx/Oropharynx (NP/OP). DNA extraction is a prerequisite for most culture-independent techniques used to identify pathogens in the NP/OP. However, components of DNA extraction kits differ thereby giving rise to differences in performance. We compared the DNA concentration and the detection of three pathogens in the NP/OP using the discontinued DNeasy PowerSoil Kit (Kit DP) and the DNeasy PowerLyzer PowerSoil Kit (Kit DPP). METHODS: DNA was extracted from the same set of 103 NP/OP samples using the two kits. DNA concentration was measured using the Qubit 2.0 Fluorometer. Real-time Polymerase Chain reaction (RT-PCR) was done using the QuantStudio 7-flex system to detect three pathogens: S. pneumoniae, H. influenzae, and N. meningitidis. Bland-Altman statistics and plots were used to determine the threshold cycle (Ct) value agreement for the two kits. RESULTS: The average DNA concentration from kit DPP was higher than Kit DP; 1235.6 ng/ml (SD = 1368.3) vs 884.9 ng/ml (SD = 1095.3), p = 0.002. Using a Ct value cutoff of 40 for positivity, the concordance for the presence of S. pneumoniae was 82% (84/102); 94%(96/103) for N. meningitidis and 92%(95/103) for H. influenzae. Kit DP proportionately resulted in higher Ct values than Kit DPP for all pathogens. The Ct value bias of measurement for S. pneumoniae was +2.4 (95% CI, 1.9-3.0), +1.4 (95% CI, 0.9-1.9) for N. meningitidis and +1.4 (95% CI, 0.2-2.5) for H. influenzae. CONCLUSION: The higher DNA concentration obtained using kit DPP could increase the chances of recovering low abundant bacteria. The PCR results were reproducible for more than 90% of the samples for the gram-negative H. influenzae and N. meningitidis. Ct value variations of the kits must be taken into consideration when comparing studies that have used the two kits.


picture_as_pdf
Khan-etal-2023-Comparison-of-dna-concentration-and.pdf
subject
Published Version
Available under Creative Commons: Attribution 4.0

View Download

Atom BibTeX OpenURL ContextObject in Span Multiline CSV OpenURL ContextObject Dublin Core Dublin Core MPEG-21 DIDL Data Cite XML EndNote HTML Citation JSON MARC (ASCII) MARC (ISO 2709) METS MODS RDF+N3 RDF+N-Triples RDF+XML RIOXX2 XML Reference Manager Refer Simple Metadata ASCII Citation EP3 XML
Export

Downloads