Performance characteristics of five antigen-detecting rapid diagnostic test (Ag-RDT) for SARS-CoV-2 asymptomatic infection: a head-to-head benchmark comparison.

Bàrbara Baro ; Pau Rodo ; Dan Ouchi ; Antoni E Bordoy ; Emilio N Saya Amaro ; Sergi V Salsench ; Sònia Molinos ; Andrea Alemany ; Maria Ubals ; Marc Corbacho-Monné ; +12 more... Pere Millat-Martinez ; Michael Marks ORCID logo ; Bonaventura Clotet ; Nuria Prat ; Oriol Estrada ; Marc Vilar ; Jordi Ara ; Martí Vall-Mayans ; Camila G-Beiras ; Quique Bassat ; Ignacio Blanco ; Oriol Mitjà ; (2021) Performance characteristics of five antigen-detecting rapid diagnostic test (Ag-RDT) for SARS-CoV-2 asymptomatic infection: a head-to-head benchmark comparison. Journal of Infection, 82 (6). pp. 269-275. ISSN 0163-4453 DOI: 10.1016/j.jinf.2021.04.009
Copy

BACKGROUND: Mass testing for early identification and isolation of infectious COVID-19 individuals is efficacious for reducing disease spread. Antigen-detecting rapid diagnostic tests (Ag-RDT) may be suitable for testing strategies; however, benchmark comparisons are scarce. METHODS: We used 286 nasopharyngeal specimens from unexposed asymptomatic individuals collected between December 2020 and January 2021 to assess five Ag-RDTs marketed by Abbott, Siemens, Roche Diagnostics, Lepu Medical, and Surescreen. RESULTS: For the overall sample, the performance parameters of Ag-RDTs were as follows: Abbott assay, sensitivity 38.6% (95%CI 29.1-48.8) and specificity 99.5% (97-100%); Siemens, sensitivity 51.5% (41.3-61.6) and specificity 98.4% (95.3-99.6); Roche, sensitivity 43.6% (33.7-53.8) and specificity 96.2% (92.4-98.5); Lepu, sensitivity 45.5% (35.6-55.8) and specificity 89.2% (83.8-93.3%); Surescreen, sensitivity 28.8% (20.2-38.6) and specificity 97.8% (94.5-99.4%). For specimens with cycle threshold (Ct) <30 in RT-qPCR, all Ag-RDT achieved a sensitivity ≥70%. The modelled negative- and positive-predictive value for 1% prevalence were >99% and <50%, respectively. CONCLUSIONS: When screening unexposed asymptomatic individuals, two Ag-RDTs achieved sensitivity ≥80% for specimens with Ct<30 and specificity ≥96%. The estimated negative predictive value suggests the suitability of Ag-RDTs for mass screenings of SARS-CoV-2 infection in the general population.


picture_as_pdf
Baro_etal_202-Performance-characteristics-of-five-antigen-detectingYJINF-D-21-00509_R1.pdf
subject
Accepted Version
Available under Creative Commons: Attribution-NonCommercial-No Derivative Works 3.0

View Download

Atom BibTeX OpenURL ContextObject in Span Multiline CSV OpenURL ContextObject Dublin Core Dublin Core MPEG-21 DIDL Data Cite XML EndNote HTML Citation JSON MARC (ASCII) MARC (ISO 2709) METS MODS RDF+N3 RDF+N-Triples RDF+XML RIOXX2 XML Reference Manager Refer Simple Metadata ASCII Citation EP3 XML
Export

Downloads