Enhancing patient safety with an electronic results checking system in a large HIV outpatient service.

DB Nugent ; N Uthayakumar ; RA Ferrand ORCID logo ; SG Edwards ; R Miller ; P Benn ; (2013) Enhancing patient safety with an electronic results checking system in a large HIV outpatient service. British journal of hospital medicine (London, England, 74 (8). pp. 465-468. ISSN 1750-8460 DOI: 10.12968/hmed.2013.74.8.465
Copy

OBJECTIVE: To establish whether an automated electronic tracker system for reporting blood results would expedite clinician review of abnormal results in HIV-positive outpatients and to pilot the use of this system in routine clinical practice. SETTING: An outpatient service in central London providing specialist HIV-related care to 3900 HIV positive patients. DESIGN: A comparison of the time taken from sampling to identification and clinician review of abnormal blood results for biochemical tests between the original paper-based checking system and an automated electronic system during a 3-week pilot. RESULTS: Of 513 patients undergoing one or more blood tests, 296 (57%) had one or more biochemical abnormalities identified by electronic checking system. Out of 371 biochemical abnormalities, 307 (82.7%) were identified simultaneously by the paper-based system. Of the 307, 33 (10.7%) were classified as urgent, 130 (42.3%) as non-urgent and 144 (46.9%) as not clinically significant. The median interval between sampling and receipt of results was 1 (interquartile range 1-2) vs 4 days ( interquartile range 3-5), P <0.0001; clinician review 3 (interquartile range 1-4) vs 3 days (interquartile range 3-6), P<0.037; and review of non-urgent abnormalities by the regular clinician 2 (interquartile range 1-4) vs 10 days ( interquartile range 9-12), P=0.136, for electronic and paper-based systems respectively. Seven (11%) of the missing paper-based system results were classified as urgent. The electronic system missed three abnormalities as a result of a software processing error which was subsequently corrected. CONCLUSIONS: The electronic tracker system allows faster identification of biochemical abnormalities and allowed faster review of these results by clinicians. The pilot study allowed for a software error to be identified and corrected before full implementation. The system has since integrated successfully into routine clinical practice.

Full text not available from this repository.

Atom BibTeX OpenURL ContextObject in Span Multiline CSV OpenURL ContextObject Dublin Core Dublin Core MPEG-21 DIDL Data Cite XML EndNote HTML Citation JSON MARC (ASCII) MARC (ISO 2709) METS MODS RDF+N3 RDF+N-Triples RDF+XML RIOXX2 XML Reference Manager Refer Simple Metadata ASCII Citation EP3 XML
Export

Downloads