Hopkins, Heidi; González, Iveth J; Polley, Spencer D; Angutoko, Patrick; Ategeka, John; Asiimwe, Caroline; Agaba, Bosco; Kyabayinze, Daniel J; Sutherland, Colin J; Perkins, Mark D; +1 more... Bell, David; (2013) Highly sensitive detection of malaria parasitemia in a malaria-endemic setting: performance of a new loop-mediated isothermal amplification kit in a remote clinic in Uganda. The Journal of infectious diseases, 208 (4). pp. 645-652. ISSN 0022-1899 DOI: https://doi.org/10.1093/infdis/jit184
Permanent Identifier
Use this Digital Object Identifier when citing or linking to this resource.
Abstract
BACKGROUND: Current malaria diagnostic tests, including microscopy and antigen-detecting rapid tests, cannot reliably detect low-density infections. Molecular methods such as polymerase chain reaction (PCR) are highly sensitive but remain too complex for field deployment. A new commercial molecular assay based on loop-mediated isothermal amplification (LAMP) was assessed for field use. METHODS: Malaria LAMP (Eiken Chemical, Japan) was evaluated for samples from 272 outpatients at a rural Ugandan clinic and compared with expert microscopy, nested PCR, and quantitative PCR (qPCR). Two technicians performed the assay after 3 days of training, using 2 alternative blood sample-preparation methods and visual interpretation of results by fluorescence assay. RESULTS: Compared with 3-well nested PCR, the sensitivity of both LAMP and single-well nested PCR was 90%; the microscopy sensitivity was 51%. For samples with a Plasmodium falciparum qPCR titer of ≥ 2 parasites/µL, LAMP sensitivity was 97.8% (95% confidence interval, 93.7%-99.5%). Most false-negative LAMP results involved samples with parasitemia levels detectable by 3-well nested PCR but very low or undetectable by qPCR. CONCLUSIONS: Malaria LAMP in a remote Ugandan clinic achieved sensitivity similar to that of single-well nested PCR in a United Kingdom reference laboratory. LAMP dramatically lowers the detection threshold achievable in malaria-endemic settings, providing a new tool for diagnosis, surveillance, and screening in elimination strategies.
Item Type | Article |
---|---|
Keywords | malaria, diagnosis, LAMP, loop-mediated isothermal amplification, sensitivity and specificity, PCR, polymerase chain reaction, molecular, diagnosis, DNA, Plasmodium falciparum, Uganda, Africa, polymerase-chain-reaction, real-time pcr, plasmodium-falciparum, infections, transmission intensity, mixed infections, high prevalence, reaction assay, diagnosis, dna, blood |
Faculty and Department |
Faculty of Infectious and Tropical Diseases > Dept of Disease Control Faculty of Infectious and Tropical Diseases > Department of Infection Biology |
Research Centre | Malaria Centre |
PubMed ID | 23633405 |
ISI | 322412100014 |
Related URLs |
Download
Filename: jit184.pdf
Licence: Creative Commons: Attribution-Noncommercial-No Derivative Works 3.0
Download