Human saliva as a source of anti-malarial antibodies to examine population exposure to Plasmodium falciparum.


Tabernero Estevez, P; Satoguina, J; Nwakanma, DC; West, S; Conway, DJ; Drakeley, CJ; (2011) Human saliva as a source of anti-malarial antibodies to examine population exposure to Plasmodium falciparum. Malar J, 10 (1). p. 104. ISSN 1475-2875 DOI: https://doi.org/10.1186/1475-2875-10-104

[img]
Preview
Text - Published Version
License:

Download (291kB) | Preview

Abstract

ABSTRACT: BACKGROUND: Antibody responses to malaria antigens reflect exposure to parasites, and seroprevalence correlates with malaria transmission intensity. Antibodies are routinely measured in sera or on dried blood spots but a non-invasive method would provide extra utility in sampling general populations. Saliva is already in use in the detection of plasma-derived IgM and IgG to viral infections. In this study, antibodies to Plasmodium falciparum merozoite antigens were compared between blood and saliva samples from the same individuals in unlinked surveys conducted in Tanzania and The Gambia. METHODS: In Tanzania, 53 individuals provided paired fingerprick blood and saliva sample using two commercially available sampling devices. In the Gambia, archived plasma and saliva samples collected from 200 children in the Farafenni area in a cross-sectional survey were analyzed.. IgG antibodies against P. falciparum antigens, Merozoite Surface Protein-1 (MSP-119) and Apical membrane Antigen (AMA-1) were measured by ELISA in paired saliva and blood samples from both sites. Antibody levels were compared as continuous optical density (OD) values and by sero-positivity. RESULTS: Significant correlations between saliva and plasma antibody levels were seen in Tanzania for both antigens, AMA-1(r2 range 0.93 to 0.89, p<0.001) and MSP-119 (r2 range 0.93 to 0.75, p<0.001), with a weaker correlation for results from The Gambia (r2range 0.64 to 0.63, p<0.01).. When assessed as seropositivity and compared with plasma, sensitivity and specificity were good with saliva antibody levels to both AMA-1 and MSP-119 (sensitivity range 64 -77% and specificity range 91-100% & 47-67% and 90-97% respectively) over the different sample sets. CONCLUSIONS: These data demonstrate anti- malarial antibodies can be detected in saliva and correlate strongly with levels in plasma. This non-invasive relatively simple collection method will be potentially useful for general population surveys, and particularly in migratory populations or those with infrequent contact with health services or opposed to blood withdrawal. Further studies will be needed to optimize collection methods, standardize volumes and content and develop controls.

Item Type: Article
Faculty and Department: Faculty of Infectious and Tropical Diseases > Dept of Pathogen Molecular Biology
Faculty of Infectious and Tropical Diseases > Dept of Immunology and Infection
Research Centre: Malaria Centre
PubMed ID: 21527045
Web of Science ID: 291597700001
URI: http://researchonline.lshtm.ac.uk/id/eprint/781

Statistics


Download activity - last 12 months
Downloads since deposit
232Downloads
345Hits
Accesses by country - last 12 months
Accesses by referrer - last 12 months
Impact and interest
Additional statistics for this record are available via IRStats2

Actions (login required)

Edit Item Edit Item